Program your water softener. Set the time of day, hardness and capacity if necessary. Here is where you will need to refer your owner's manual for your particular water softener settings and programming. Once your softener is programmed advance your controller to manual regeneration. The regeneration process can take a while. 760 Controller- Electronic metered-demand (volumetric) controller which regenerates based on the water usage of the installation site. A calendar override is a standard feature on this controller. The Logix Series will operate on both the 255 and Performa valve body series. Time & Day Regen Time & Day Salt SU MO TU WE TH FR SA DAYS. The Logix 760 and 762 controllers are used primarily with the Autotrol 255 and 268 valves. There may come a time in the life of your water softener where you need to do a master reset of the Autotrol Logix controller. If your Autotrol control valve uses the Logix 760. Manual override regeneration provides extra soft water exactly when you need it The Autotrol LOGIX 268/760 Meter-Demand system can cut salt and water use by as much as 40%! Unlike timer-based systems, the meter-demand system regenerates only when necessary.
The Logix 760 and 762 controllers are used primarily with the Autotrol 255 and 268 valves. There may come a time in the life of your water softener where you need to do a master reset of the Autotrol Logix controller. If your Autotrol control valve uses the Logix 760 or 762 controller then you can use these instructions to perform a master reset to get it back to the factory defaults. Warning - this reset procedure will erase all stored values including historical data. You'll know if you have a Logix 760 or 762 if yours looks like this:
Mac os for pc iso download. Here's how to do the reset:
- Press and hold SET and DOWN simultaneously for 5 seconds.
- 'H0' and the system’s set resin volume (or 'F' mode) will be displayed.
- If a history value other than 'H0' is displayed, use the up arrow to scroll through the settings until 'H0' is displayed.
- To reset the control, press and hold SET for 5 seconds.
- The control will be reset to an un-programmed state.
Logix 760 Water Softener Manuals
The control valve is now reset to factory default values and you can proceed to the following resources for reprogramming instructions. Look for the section titled 'Initial Setup'
Canon mx870 software mac download. The most important step in the initial setup is to make sure that the media volume is set correctly. Here are the grain capacities for water softeners and corresponding resin volumes:
- 24,000 grain = 0.75 cubic feet
- 32,000 grain = 1.0 cubic feet
- 40,000 grain = 1.25 cubic feet
- 48,000 grain = 1.5 cubic feet
- 64,000 grain = 2.0 cubic feet
- 96,000 grain = 3.0 cubic feet
If you happened to find this page because you're looking for a new Autotrol softener, you're in luck - we sell them! And you can find them here.
Autotrol 255/760 Logix Water Softener Manual
Discussion in 'Water Softener Forum, Questions and Answers' started by Pitt742, Feb 8, 2012.
Logix 760 Water Softener Troubleshooting
Forum | Title | Date |
---|---|---|
Water Softener Forum, Questions and Answers | Problem and Optimal Settings for Logix 762 with 268 Valve | Jul 28, 2015 |
Water Softener Forum, Questions and Answers | Logix 740 Timers, Blank Displays | Aug 18, 2016 |
Water Softener Forum, Questions and Answers | Logix 760 transformer | Feb 3, 2014 |
Water Softener Forum, Questions and Answers | Water Softener settings for Fleck 7000 | Dec 2, 2020 |
Water Softener Forum, Questions and Answers | Help with Softener Settings for 0.75 CUFT System | Nov 17, 2020 |